Biocompatible Medical Grade PEI 3D Printing Filament
We supply Medical Grade PEI (Ultem™ HU1000 / 1010 Equivalent) 3D Filament in 1.75mm and 2.85mm (±0.03 tolerance). Fully certified to ISO 10993 and USP Class VI biocompatibility, this high-temperature FDM filament withstands repeated steam autoclaving (134°C), EtO, Gamma, and plasma sterilization. Ideal for custom surgical guides, orthopedic trial implants, and autoclavable dental instruments. Share your specs for a fast quote.
Product information
Published information supports preliminary product selection. Confirm the exact grade, dimensions, tolerances, documentation and application suitability with the quotation for your order.
Description
Medical Grade PEI 3D Filament is an advanced biocompatible polymer engineered for medical device prototyping, autoclavable surgical tools, and patient-specific aids. Formulated from premium Polyetherimide resin, this translucent amber filament delivers high mechanical strength (tensile strength ~90 MPa), rigid dimensional stability, and extreme resistance to harsh hospital disinfectants and lipids.
Featuring a glass transition temperature (𝑇𝑔) of 217°C and HDT of 200°C, it complies with strict ISO 10993 and USP Class VI tissue/blood contact safety standards. Vacuum-sealed in aluminum foil bags with desiccant, it enables warp-free 3D printing of custom surgical cutting guides, orthopedic trial implants, dental impression trays, and fluidic manifolds subjected to multi-cycle sterilization routines.
Property & Sterilization Datasheet Summary
| Parameter / Property | Technical Value / Standard |
| Resin Grade & Compliance | Medical PEI (Ultem HU1000 Equivalent) / ISO 10993 & USP Class VI |
| Filament Diameters | 1.75 mm / 2.85 mm (Tight Tolerance ±0.03) |
| Thermal Limits | 𝑇𝑔:217℃/HDT @ 1.8MPa: 200°C / Continuous: 170°C |
| Sterilization Resistance | Autoclave (134°C Steam), EtO, Gamma Ray, Hydrogen Peroxide Plasma |
| Disinfectant Resistance | Excellent resistance to hospital lipids, alcohols, and chemical cleansers |
| Recommended Printing Temps | Nozzle: 350–390°C / Bed: 140–160°C / Chamber: 90–150°C |
| Spool Packaging | 0.5 kg / 1.0 kg / 2.5 kg Spools (Aluminum Foil Vacuum Sealed) |
How this product is normally specified
This product is supplied as medical-grade FDM filament spools for industrial high-temp 3D printers:
-
Filament Diameter: 1.75 mm or 2.85 mm (±0.03 tolerance)
-
Biocompatibility Level: ISO 10993 & USP Class VI tissue/blood contact certified
-
Sterilization Needs: Multi-cycle steam autoclaving (134°C), EtO, or Gamma radiation
-
Printer Hardware: High-temp nozzle (350 -390℃) and heated chamber (<90℃)
Where this material can fit
Typical applications for biocompatible medical grade PEI filament include:
-
Surgical & Orthopedic Tools: Custom surgical cutting guides, drill templates, and orthopedic trial implants
-
Dental & Maxillofacial: Autoclavable dental impression trays, guides, and alignment tools
-
Medical Devices & Housings: Disinfectant-resistant sensor housings, fluidic manifolds, and ventilator parts
-
Patient-Specific Prosthetics: High-strength, lightweight customized structural prosthetics and orthotics
What to confirm before ordering
To recommend the right medical PEI filament specification, please confirm:
-
Required filament diameter (1.75mm vs. 2.85mm) and spool weight
-
Biocompatibility certification level (ISO 10993 / USP Class VI requirements)
-
Target sterilization protocol (134°C steam autoclave, EtO, Gamma, or plasma)
-
Required trial quantity and estimated commercial demand
Send us the information you have. We will review technical details before confirming the quotation.
Material overview
Understanding PEI (Polyetherimide)
Why engineers use it
- Good heat resistance and stiffness for structural and electrical parts.
- Stable dimensions and predictable processing in suitable equipment.
- Inherent flame, smoke and electrical performance for many technical applications.
- Available in natural amber and opaque or reinforced grades.
- Can be molded, machined or printed where the appropriate material form is available.
Limits to consider
- Some chemicals and stress-cracking agents require careful compatibility review.
- Moisture control before high-temperature processing is important.
- Continuous chemical or wear duty may favor PEEK or PPS.
- Reinforced grades change impact, surface and directional properties.
- Regulated uses require the correct documented grade, not a generic PEI designation.
Grades and product forms
Unfilled PEI emphasizes the base material’s thermal, electrical and dimensional balance. Glass-fiber grades improve stiffness and movement control but change toughness and surface finish. Medical, aerospace or food-contact projects must identify the exact documentation requirement before grade selection.
Performance points to review
| Evaluation area | Why it matters | Information to provide |
|---|---|---|
| Temperature behavior | Useful performance under elevated or changing temperature | Continuous and peak temperature, cycle length and time at load |
| Mechanical response | Strength and stiffness must match the real part geometry | Load direction, stress level, impact and fatigue expectations |
| Environmental resistance | Fluids, cleaning agents and atmosphere can change service life | Chemical name, concentration, temperature and exposure time |
| Dimensional control | Tight-tolerance parts depend on both material and processing | Finished dimensions, tolerances and assembly conditions |
| Electrical or insulation needs | Electrical requirements may influence grade and thickness | Voltage, dielectric, conductivity or insulation target |
These are engineering discussion points, not guaranteed property values. Final acceptance criteria should be agreed for the selected grade, process and order.
Typical application directions
These examples show where the material may be evaluated. They do not replace a suitability review for the finished component.
Preparing a high-temperature printing project
Provide filament diameter, printer model, nozzle and chamber capability, drying method, build geometry, support strategy and annealing plan. A high-performance filament cannot compensate for a printer that lacks the necessary thermal control.
Where the application is critical, define what a successful trial looks like before material is ordered: dimensions after processing, visual condition, mechanical response, assembly fit or another measurable result.
When another material may be better
PEEK may provide a larger performance margin in more severe heat or chemical service, while lower-cost engineering plastics may be sufficient for moderate conditions. PEI is often chosen when its specific balance of thermal, electrical and structural properties fits the part.
We recommend sharing the current material and the reason it is being reconsidered. Cost, processability, supply form and inspection burden belong in the decision alongside technical performance.
Information needed for an accurate quotation
A useful RFQ reduces follow-up questions and helps us distinguish between a material request and a finished-part requirement.
| Product form | Raw material, stock shape, semi-finished blank or completed part |
|---|---|
| Dimensions | Nominal size, finished size and tolerances |
| Quantity | Trial quantity, first order and estimated annual demand |
| Application | Part function and current material, if any |
| Operating temperature | Continuous range, peak temperature and cycle duration |
| Environment | Chemicals, gases, moisture, pressure, vacuum or outdoor exposure |
| Mechanical duty | Load, speed, impact, wear and mating components |
| Documentation | Drawing revision, inspection, traceability or compliance needs |
| Printing setup | Printer, nozzle, chamber, build plate, drying and annealing capability |
Frequently asked questions
Can I request a sample or trial quantity?
Trial quantities can be discussed according to product form and availability. Tell us what you need to prove during the trial, the intended process and the expected production quantity if the test succeeds.
Do you provide a data sheet or material documentation?
Available documentation depends on the selected material and supply route. List the documents required by engineering, purchasing or quality when you inquire so they can be checked before quotation.
Can the grade be selected from a product name alone?
No. Similar product names can cover different grades, colors, fillers and processes. Selection should be based on the finished application, environment and required property balance.
Can you supply custom dimensions or finished parts?
Custom sizes, blanks or finished parts can be reviewed where appropriate. A drawing with tolerances, quantity and material requirement is the best basis for quotation.
How should we evaluate an alternative to our current material?
Share the current grade, the part’s service conditions and the reason for changing it. A useful comparison looks at failure mode, processing, life, inspection and total project cost—not only a single property value.
What determines lead time?
Lead time depends on product form, grade, size, quantity, documentation, machining and current availability. Confirm the required delivery date and destination with the RFQ rather than assuming a standard schedule.
Send the drawing, application and quantity. We will use the project details to prepare a practical material and supply discussion.






Reviews
There are no reviews yet.